Tool · Conduit Material Selector
Which conduit fits your conditions?
Pick the conditions your raceway will face. The selector compares PVC-coated, stainless, fiberglass, PVC and galvanized rigid steel against them, and points you to the spec guide for the best fits.
1. Pick your conditions
Choose everything that applies to the run. The best fits move to the top.
2. Compare the options
Pick one or more conditions above to rank the materials. Until then, every condition is shown.
PVC-coated rigid
Robroy Plasti-BondAll conditions shownStrong fitGood fit, check detailsNot typical for one or more conditions
- Corrosive gases or chemicals: 40 mil PVC jacket and urethane interior; ETL PVC-001 verified.
- Washdown or sanitary area: Used in washdown areas. Protect the coating from damage.
- Coastal or salt air: The PVC jacket protects the steel or aluminum from salt air.
- Direct burial or underground: Underground burial system with coated elbows and sealing locknuts.
- Hazardous (classified) location: Coated UL 1203 hazardous-location fittings.
- Weight, labor or long runs: Heavier, and the coating needs careful handling.
- Exposed to physical damage: Rigid metal core under the coating.
- Non-conductive raceway wanted: Conductive metal under the coating.
Stainless steel
Robroy StainlessAll conditions shownStrong fitGood fit, check detailsNot typical for one or more conditions
- Corrosive gases or chemicals: No coating to damage. Confirm the grade against the chemicals.
- Washdown or sanitary area: Hygienic product family and a sanitary support system.
- Coastal or salt air: Corrosion resistant. Confirm the grade for chloride exposure.
- Direct burial or underground: Possible, but not a typical choice for buried runs.
- Hazardous (classified) location: Confirm listed hazardous-location fittings for the classification.
- Weight, labor or long runs: Metal weight, and supports must also be stainless.
- Exposed to physical damage: Rigid metal wall.
- Non-conductive raceway wanted: Conductive metal raceway.
Fiberglass (RTRC)
Champion FiberglassAll conditions shownStrong fitGood fit, check detailsNot typical for one or more conditions
- Corrosive gases or chemicals: Won't rust. Check the resin against the chemicals present.
- Washdown or sanitary area: Won't rust. Confirm the cleaning chemicals with Champion.
- Coastal or salt air: Champion lists port and coastal work among its core markets.
- Direct burial or underground: Fiberglass duct and low-friction elbows for duct banks.
- Hazardous (classified) location: Champion Haz Duct XW covers Class I, Division 2.
- Weight, labor or long runs: Up to 1/5 the weight of comparable steel; extended listed spans.
- Exposed to physical damage: Pick the wall type for the exposure; XW for high-impact areas.
- Non-conductive raceway wanted: Non-conductive. Champion notes grounding bushings aren't needed for fault protection.
PVC
Wheatland PVCAll conditions shownStrong fitGood fit, check detailsNot typical for one or more conditions
- Corrosive gases or chemicals: Resists many chemicals. Check the exposure and impact risk.
- Washdown or sanitary area: Won't rust. Check cleaning chemicals and impact exposure.
- Coastal or salt air: Won't rust. Check UV exposure and physical protection.
- Direct burial or underground: Common for direct burial and encased duct. Watch elbow wear.
- Hazardous (classified) location: Limited in classified locations. Check the NEC for the area.
- Weight, labor or long runs: Light and easy to handle.
- Exposed to physical damage: Use a heavier wall where it's exposed to damage.
- Non-conductive raceway wanted: Non-conductive.
Galvanized rigid steel
WheatlandAll conditions shownStrong fitGood fit, check detailsNot typical for one or more conditions
- Corrosive gases or chemicals: Galvanizing can be attacked. Usually needs added protection.
- Washdown or sanitary area: Not typically used in washdown or sanitary areas.
- Coastal or salt air: Salt air shortens galvanized life. Consider added protection.
- Direct burial or underground: Often needs supplemental corrosion protection in soil (NEC 300.6).
- Hazardous (classified) location: Rigid metal conduit is a standard wiring method in classified areas.
- Weight, labor or long runs: Heavier to handle and support than non-metallic options.
- Exposed to physical damage: Rigid steel wall.
- Non-conductive raceway wanted: Conductive metal raceway.
General guidance drawn from manufacturer materials and common practice. It doesn't replace the engineer of record's judgment, the NEC, or the manufacturer's current data. Galvanized rigid steel is included as the common baseline.
Full comparison
Every condition against every material, in one view.
| Condition | PVC-coated rigidRobroy Plasti-Bond | Stainless steelRobroy Stainless | Fiberglass (RTRC)Champion Fiberglass | PVCWheatland PVC | Galvanized rigid steelWheatland |
|---|---|---|---|---|---|
| Corrosive gases or chemicals | Good fit40 mil PVC jacket and urethane interior; ETL PVC-001 verified. | Good fitNo coating to damage. Confirm the grade against the chemicals. | Good fitWon't rust. Check the resin against the chemicals present. | Check detailsResists many chemicals. Check the exposure and impact risk. | Check detailsGalvanizing can be attacked. Usually needs added protection. |
| Washdown or sanitary area | Check detailsUsed in washdown areas. Protect the coating from damage. | Good fitHygienic product family and a sanitary support system. | Check detailsWon't rust. Confirm the cleaning chemicals with Champion. | Check detailsWon't rust. Check cleaning chemicals and impact exposure. | Not typicalNot typically used in washdown or sanitary areas. |
| Coastal or salt air | Good fitThe PVC jacket protects the steel or aluminum from salt air. | Good fitCorrosion resistant. Confirm the grade for chloride exposure. | Good fitChampion lists port and coastal work among its core markets. | Check detailsWon't rust. Check UV exposure and physical protection. | Check detailsSalt air shortens galvanized life. Consider added protection. |
| Direct burial or underground | Good fitUnderground burial system with coated elbows and sealing locknuts. | Check detailsPossible, but not a typical choice for buried runs. | Good fitFiberglass duct and low-friction elbows for duct banks. | Good fitCommon for direct burial and encased duct. Watch elbow wear. | Check detailsOften needs supplemental corrosion protection in soil (NEC 300.6). |
| Hazardous (classified) location | Good fitCoated UL 1203 hazardous-location fittings. | Check detailsConfirm listed hazardous-location fittings for the classification. | Check detailsChampion Haz Duct XW covers Class I, Division 2. | Check detailsLimited in classified locations. Check the NEC for the area. | Good fitRigid metal conduit is a standard wiring method in classified areas. |
| Weight, labor or long runs | Check detailsHeavier, and the coating needs careful handling. | Check detailsMetal weight, and supports must also be stainless. | Good fitUp to 1/5 the weight of comparable steel; extended listed spans. | Good fitLight and easy to handle. | Check detailsHeavier to handle and support than non-metallic options. |
| Exposed to physical damage | Good fitRigid metal core under the coating. | Good fitRigid metal wall. | Check detailsPick the wall type for the exposure; XW for high-impact areas. | Check detailsUse a heavier wall where it's exposed to damage. | Good fitRigid steel wall. |
| Non-conductive raceway wanted | Not typicalConductive metal under the coating. | Not typicalConductive metal raceway. | Good fitNon-conductive. Champion notes grounding bushings aren't needed for fault protection. | Good fitNon-conductive. | Not typicalConductive metal raceway. |
Lines we represent
Still deciding?
Send us the conditions and the run. Our specifications team will talk it through and point you to the right spec language.
General guidance drawn from manufacturer materials and common practice. Confirm current listings and specifications with the manufacturer and the NEC before issuing documents.